列間空調

 提示:點擊圖片可以放大

As everyone knows, the heavy load (w/m2) in computer applications is mainly caused by the increasing loads of data center racks and it finally produces heat load density which is relatively high. Because of unpredictable heavy loads, the remarkable performance of cooling system is required, at the same time occupies small space, so as provides more space for equipment in the room.

衆所周知,機房應用中的負載負荷(w/m2)不斷的上升,主要是由數據中心機架負荷的增加而造成,最終産生了比較高的熱負荷密度。這要求空調系統具有更卓越的性能,同時盡可能占小的空間,從而為機房設備提供更大的空間。

Air-Blade has the advantage of energy saving in the market of air-conditioning because the space is the same as the value.

Air-Blade是市場上最具節能性的空調。 因為空間意味着價值。

Blade series is applicable for the server (horizontal blower type) with a surrounding air inlet and split system.It can meet the needs of a new generation of computer room and server center refrigeration standard. The refrigeration density for the blade series is very high (on the surface of 0.8mm2 reaches as high as 25KW). By using the modularized design including adaptive logic system can be managed through network, and the blade series is the best partner for the architecture of blade server and high density equipment. It is the ideal refrigeration system for the telephone, internet, data center, service center, and high density of buildings.

刀片風用在服務器上(水平送風式)有一款周圍進氣和風分體機系統,可滿足新一代計算機房和服務器中心制冷标準。具有極高的制冷密度(在0.8mm2的表面上 高達25KW)。采用模坱化設計,包含自适應羅輯系統,可通過連網進行管理,是刀片服務器架構和高密度設備的最佳合作夥伴,是成為電話局、數據中心、互聯 網、服務中心和高密度建築物的理想制冷系統。

Characteristicfor Air-Blade (刀片風的特點):

Precision air inlet: Air volume can be controlled automatically according to the heat load and the needs of airflow;

精密送風:按需求送風風量可根據熱負荷自動控制;

Thenearest air inlet: The nearest air inlet and channelized closed system can achieve precise control of airflow;

就近送風:與信道封閉系統配合,使用可實現氣流精密可控;

Fan with energy saving: The distance of wind blowing is short, the air circulation resistance is small, and the power consumption of the fan isless;

風機節能:送風距離短,送回風循環風阻小,風機功耗小;

Refrigeration system with energy saving: It can be matched with the channelized closed system, used to work at the high temperature environment, and is highly efficient and energy saving;

制冷系統節能:可與信道封閉系統配合,使用在高回風溫度下工作,高效節能;

Installation easily: There is no need to install ventilation system under the ground. The cooling system is installed inside the cabinet which sucks out the rear or valve of the heat from the machine. The cold air is passed through the cooling channel and out in the front side of machine. The equipment is capable of absorbing heat from the cooling channel. The cooling facility is also applicable to update and upgrade under the existing structure of regulations.

安裝簡易:在地闆下無需安裝通氣和通風系統。安裝在機櫃内便于冷卻,從而吸出後部或閥通道的熱氣來自于機器,所謂的冷道從前側放(冷卻後),設備可從冷通道吸熱氣冷卻,且也适用于更新和升級依據現有規定的結構。

列間空調精密空調 機房精密空調

This chart is for reference only, the new design of components and structures for the unit will change depending on the actual situation.
此工程圖僅供參考,新機型所使用的元件及機組内部的設計會根據實際狀況而有所變動。